Analyze calibration curve quality using linear and weighted regression, residual diagnostics, lack-of-fit testing, and LOD/LOQ calculations for HPLC, LC-MS, and UV-Vis methods.
The Calibration Curve Quality Checker is a scientifically rigorous analytical tool designed for evaluating calibration model performance in HPLC, LC-MS, GC, UV-Visible spectroscopy, and other quantitative instrumental methods. This application enables laboratory scientists, analytical chemists, and method developers to assess calibration accuracy, regression integrity, and quantitative reliability using statistically correct and transparent calculations.
This tool supports:
Ordinary Least Squares (OLS) linear regression
Weighted linear regression (1, 1/x, 1/x², 1/y, 1/y², 1/ŷ²)
Optional quadratic regression with adjusted R² and AIC
Intercept forcing (zero-intercept modeling)
Replicate handling with pure error and lack-of-fit testing
Comprehensive calibration diagnostics include:
Regression coefficients with standard errors and confidence intervals
R² and adjusted R²
RMSE and residual standard error
Studentized residuals, leverage, and Cook’s distance
Residual pattern analysis for curvature and heteroscedasticity
Back-calculated concentrations with bias and %bias
Inverse prediction for unknown samples with confidence intervals
Optional LOD and LOQ estimation using statistically defined methods
The Calibration Curve Quality Checker helps identify:
Nonlinearity and curvature
Heteroscedastic response behavior
High-leverage calibration points
Outliers and influential observations
Systematic bias at low or high concentration levels
Poor model selection (linear vs quadratic vs weighted)
This tool is ideal for:
Analytical method validation
Quantitative method development
Regulatory documentation preparation
Teaching calibration statistics in analytical chemistry
Evaluating LC-MS, HPLC-UV, GC-FID, ICP-OES, or spectroscopic calibration performance
Unlike simplistic R²-only evaluations, this application emphasizes residual diagnostics, inverse prediction accuracy, and statistical transparency, ensuring calibration curves are evaluated using sound analytical chemistry principles rather than arbitrary acceptance thresholds.
Use this Calibration Curve Quality Checker to strengthen quantitative method reliability, improve analytical accuracy, and ensure defensible calibration modeling across laboratory workflows.
Calibration Curve Quality Checker – Linear & Weighted Regression, Residual Diagnostics, LOD/LOQ Calculator for HPLC, LC-MS & UV-Vis